@article{bb190700,
        AUTHOR = "Wang, K. and Ermilov, S.A. and Su, R. and Brecht, H.P. and Oraevsky, A.A. and Anastasio, M.A.",
        TITLE = "An Imaging Model Incorporating Ultrasonic Transducer Properties for
Three-Dimensional Optoacoustic Tomography",
        JOURNAL = MedImg,
        VOLUME = "30",
        YEAR = "2011",
        NUMBER = "2",
        MONTH = "February",
        PAGES = "203-214",
        BIBSOURCE = "http://www.visionbib.com/bibliography/medical894pha1.html#TT185963"}

@article{bb190701,
        AUTHOR = "Wang, K. and Schoonover, R.W. and Su, R. and Oraevsky, A.A. and Anastasio, M.A.",
        TITLE = "Discrete Imaging Models for Three-Dimensional Optoacoustic Tomography
Using Radially Symmetric Expansion Functions",
        JOURNAL = MedImg,
        VOLUME = "33",
        YEAR = "2014",
        NUMBER = "5",
        MONTH = "May",
        PAGES = "1180-1193",
        BIBSOURCE = "http://www.visionbib.com/bibliography/medical894pha1.html#TT185964"}

@article{bb190702,
        AUTHOR = "Qian, J.L. and Stefanov, P. and Uhlmann, G. and Zhao, H.K.",
        TITLE = "An Efficient Neumann Series-Based Algorithm for Thermoacoustic and
Photoacoustic Tomography with Variable Sound Speed",
        JOURNAL = SIIMS,
        VOLUME = "4",
        YEAR = "2011",
        NUMBER = "3",
        PAGES = "850-883",
        BIBSOURCE = "http://www.visionbib.com/bibliography/medical894pha1.html#TT185965"}

@article{bb190703,
        AUTHOR = "Zhang, P.Z. and Wang, S.Z. and Wang, R.T.",
        TITLE = "Reducing frequency-domain artifacts of binary image due to coarse
sampling by repeated interpolation and smoothing of Radon projections",
        JOURNAL = JVCIR,
        VOLUME = "23",
        YEAR = "2012",
        NUMBER = "5",
        MONTH = "July",
        PAGES = "697-704",
        BIBSOURCE = "http://www.visionbib.com/bibliography/medical894pha1.html#TT185966"}

@article{bb190704,
        AUTHOR = "Dong, C. and Jin, Y.",
        TITLE = "MIMO Nonlinear Ultrasonic Tomography by Propagation and Backpropagation
Method",
        JOURNAL = IP,
        VOLUME = "22",
        YEAR = "2013",
        NUMBER = "3",
        MONTH = "March",
        PAGES = "1056-1069",
        BIBSOURCE = "http://www.visionbib.com/bibliography/medical894pha1.html#TT185967"}

@article{bb190705,
        AUTHOR = "Liu, Z. and Liu, L. and Xu, Y. and Wang, L.V.",
        TITLE = "Transcranial Thermoacoustic Tomography:
A Comparison of Two Imaging Algorithms",
        JOURNAL = MedImg,
        VOLUME = "32",
        YEAR = "2013",
        NUMBER = "2",
        MONTH = "February",
        PAGES = "289-294",
        BIBSOURCE = "http://www.visionbib.com/bibliography/medical894pha1.html#TT185968"}

@article{bb190706,
        AUTHOR = "Ren, K. and Gao, H. and Zhao, H.K.",
        TITLE = "A Hybrid Reconstruction Method for Quantitative PAT",
        JOURNAL = SIIMS,
        VOLUME = "6",
        YEAR = "2013",
        NUMBER = "1",
        PAGES = "32-55",
        BIBSOURCE = "http://www.visionbib.com/bibliography/medical894pha1.html#TT185969"}

@article{bb190707,
        AUTHOR = "Ren, K. and Zhao, H.K.",
        TITLE = "Quantitative Fluorescence Photoacoustic Tomography",
        JOURNAL = SIIMS,
        VOLUME = "6",
        YEAR = "2013",
        NUMBER = "4",
        PAGES = "2404-2429",
        BIBSOURCE = "http://www.visionbib.com/bibliography/medical894pha1.html#TT185970"}

@article{bb190708,
        AUTHOR = "Huang, C. and Wang, K. and Nie, L.M. and Wang, L.V. and Anastasio, M.A.",
        TITLE = "Full-Wave Iterative Image Reconstruction in
Photoacoustic Tomography With Acoustically Inhomogeneous Media",
        JOURNAL = MedImg,
        VOLUME = "32",
        YEAR = "2013",
        NUMBER = "6",
        PAGES = "1097-1110",
        BIBSOURCE = "http://www.visionbib.com/bibliography/medical894pha1.html#TT185971"}

@article{bb190709,
        AUTHOR = "Jeon, M. and Kim, C.",
        TITLE = "Multimodal Photoacoustic Tomography",
        JOURNAL = MultMed,
        VOLUME = "15",
        YEAR = "2013",
        NUMBER = "5",
        PAGES = "975-982",
        BIBSOURCE = "http://www.visionbib.com/bibliography/medical894pha1.html#TT185972"}

@article{bb190710,
        AUTHOR = "Choe, J.W. and Nikoozadeh, A. and Oralkan, O. and Khuri Yakub, B.T.",
        TITLE = "GPU-Based Real-Time Volumetric Ultrasound Image Reconstruction for a
Ring Array",
        JOURNAL = MedImg,
        VOLUME = "32",
        YEAR = "2013",
        NUMBER = "7",
        PAGES = "1258-1264",
        BIBSOURCE = "http://www.visionbib.com/bibliography/medical894pha1.html#TT185973"}

@article{bb190711,
        AUTHOR = "Tarvainen, T. and Pulkkinen, A. and Cox, B.T. and Kaipio, J.P. and Arridge, S.R.",
        TITLE = "Bayesian Image Reconstruction in Quantitative Photoacoustic
Tomography",
        JOURNAL = MedImg,
        VOLUME = "32",
        YEAR = "2013",
        NUMBER = "12",
        PAGES = "2287-2298",
        BIBSOURCE = "http://www.visionbib.com/bibliography/medical894pha1.html#TT185974"}

@article{bb190712,
        AUTHOR = "Pulkkinen, A. and Cox, B.T. and Arridge, S.R. and Goh, H. and Kaipio, J.P. and Tarvainen, T.",
        TITLE = "Direct Estimation of Optical Parameters From Photoacoustic Time
Series in Quantitative Photoacoustic Tomography",
        JOURNAL = MedImg,
        VOLUME = "35",
        YEAR = "2016",
        NUMBER = "11",
        MONTH = "November",
        PAGES = "2497-2508",
        BIBSOURCE = "http://www.visionbib.com/bibliography/medical894pha1.html#TT185975"}

@article{bb190713,
        AUTHOR = "Tzoumas, S. and Deliolanis, N. and Morscher, S. and Ntziachristos, V.",
        TITLE = "Unmixing Molecular Agents From Absorbing Tissue in Multispectral
Optoacoustic Tomography",
        JOURNAL = MedImg,
        VOLUME = "33",
        YEAR = "2014",
        NUMBER = "1",
        MONTH = "January",
        PAGES = "48-60",
        BIBSOURCE = "http://www.visionbib.com/bibliography/medical894pha1.html#TT185976"}

@article{bb190714,
        AUTHOR = "Birk, M. and Zapf, M. and Balzer, M. and Ruiter, N. and Becker, J.",
        TITLE = "A comprehensive comparison of GPU- and FPGA-based acceleration of
reflection image reconstruction for 3D ultrasound computer tomography",
        JOURNAL = RealTimeIP,
        VOLUME = "9",
        YEAR = "2014",
        NUMBER = "1",
        MONTH = "March",
        PAGES = "159-170",
        BIBSOURCE = "http://www.visionbib.com/bibliography/medical894pha1.html#TT185977"}

@article{bb190715,
        AUTHOR = "Dong, C.D. and Jin, Y.W. and Lu, E.",
        TITLE = "Accelerated Nonlinear Multichannel Ultrasonic Tomographic Imaging
Using Target Sparseness",
        JOURNAL = IP,
        VOLUME = "23",
        YEAR = "2014",
        NUMBER = "3",
        MONTH = "March",
        PAGES = "1379-1393",
        BIBSOURCE = "http://www.visionbib.com/bibliography/medical894pha1.html#TT185978"}

@article{bb190716,
        AUTHOR = "Caballero, M.A.A. and Gateau, J. and Dean Ben, X.L. and Ntziachristos, V.",
        TITLE = "Model-Based Optoacoustic Image Reconstruction of Large
Three-Dimensional Tomographic Datasets Acquired With an Array of
Directional Detectors",
        JOURNAL = MedImg,
        VOLUME = "33",
        YEAR = "2014",
        NUMBER = "2",
        MONTH = "February",
        PAGES = "433-443",
        BIBSOURCE = "http://www.visionbib.com/bibliography/medical894pha1.html#TT185979"}

@article{bb190717,
        AUTHOR = "Kowar, R.",
        TITLE = "On Time Reversal in Photoacoustic Tomography for Tissue Similar to
Water",
        JOURNAL = SIIMS,
        VOLUME = "7",
        YEAR = "2014",
        NUMBER = "1",
        PAGES = "509-527",
        BIBSOURCE = "http://www.visionbib.com/bibliography/medical894pha1.html#TT185980"}

@article{bb190718,
        AUTHOR = "Taruttis, A. and Rosenthal, A. and Kacprowicz, M. and Burton, N.C. and Ntziachristos, V.",
        TITLE = "Multiscale Multispectral Optoacoustic Tomography by a Stationary
Wavelet Transform Prior to Unmixing",
        JOURNAL = MedImg,
        VOLUME = "33",
        YEAR = "2014",
        NUMBER = "5",
        MONTH = "May",
        PAGES = "1194-1202",
        BIBSOURCE = "http://www.visionbib.com/bibliography/medical894pha1.html#TT185981"}

@article{bb190719,
        AUTHOR = "Teniou, S. and Meribout, M.",
        TITLE = "A Multimodal Image Reconstruction Method Using Ultrasonic Waves and
Electrical Resistance Tomography",
        JOURNAL = IP,
        VOLUME = "24",
        YEAR = "2015",
        NUMBER = "11",
        MONTH = "November",
        PAGES = "3512-3521",
        BIBSOURCE = "http://www.visionbib.com/bibliography/medical894pha1.html#TT185982"}

@article{bb190720,
        AUTHOR = "Qiu, L.Y. and Santosa, F.",
        TITLE = "Analysis of the Magnetoacoustic Tomography with Magnetic Induction",
        JOURNAL = SIIMS,
        VOLUME = "8",
        YEAR = "2015",
        NUMBER = "3",
        PAGES = "2070-2086",
        BIBSOURCE = "http://www.visionbib.com/bibliography/medical894pha1.html#TT185983"}

@article{bb190721,
        AUTHOR = "Sheng, Q. and Wang, K. and Matthews, T.P. and Xia, J. and Zhu, L. and Wang, L.V. and Anastasio, M.A.",
        TITLE = "A Constrained Variable Projection Reconstruction Method for
Photoacoustic Computed Tomography Without Accurate Knowledge of
Transducer Responses",
        JOURNAL = MedImg,
        VOLUME = "34",
        YEAR = "2015",
        NUMBER = "12",
        MONTH = "December",
        PAGES = "2443-2458",
        BIBSOURCE = "http://www.visionbib.com/bibliography/medical894pha1.html#TT185984"}

@article{bb190722,
        AUTHOR = "Lutzweiler, C. and Tzoumas, S. and Rosenthal, A. and Ntziachristos, V. and Razansky, D.",
        TITLE = "High-Throughput Sparsity-Based Inversion Scheme for Optoacoustic
Tomography",
        JOURNAL = MedImg,
        VOLUME = "35",
        YEAR = "2016",
        NUMBER = "2",
        MONTH = "February",
        PAGES = "674-684",
        BIBSOURCE = "http://www.visionbib.com/bibliography/medical894pha1.html#TT185985"}

@article{bb190723,
        AUTHOR = "Nguyen, L.V. and Kunyansky, L.A.",
        TITLE = "A Dissipative Time Reversal Technique for Photoacoustic Tomography in
a Cavity",
        JOURNAL = SIIMS,
        VOLUME = "9",
        YEAR = "2016",
        NUMBER = "2",
        PAGES = "748-769",
        BIBSOURCE = "http://www.visionbib.com/bibliography/medical894pha1.html#TT185986"}

@article{bb190724,
        AUTHOR = "Hannukainen, A. and Hyvonen, N. and Majander, H. and Tarvainen, T.",
        TITLE = "Efficient Inclusion of Total Variation Type Priors in Quantitative
Photoacoustic Tomography",
        JOURNAL = SIIMS,
        VOLUME = "9",
        YEAR = "2016",
        NUMBER = "3",
        PAGES = "1132-1153",
        BIBSOURCE = "http://www.visionbib.com/bibliography/medical894pha1.html#TT185987"}

@article{bb190725,
        AUTHOR = "Schlosser, J. and Hristov, D.",
        TITLE = "Radiolucent 4D Ultrasound Imaging:
System Design and Application to Radiotherapy Guidance",
        JOURNAL = MedImg,
        VOLUME = "35",
        YEAR = "2016",
        NUMBER = "10",
        MONTH = "October",
        PAGES = "2292-2300",
        BIBSOURCE = "http://www.visionbib.com/bibliography/medical894pha1.html#TT185988"}

@article{bb190726,
        AUTHOR = "Liu, H. and Wang, K. and Peng, D. and Li, H. and Zhu, Y. and Zhang, S. and Liu, M. and Tian, J.",
        TITLE = "Curve-Driven-Based Acoustic Inversion for Photoacoustic Tomography",
        JOURNAL = MedImg,
        VOLUME = "35",
        YEAR = "2016",
        NUMBER = "12",
        MONTH = "December",
        PAGES = "2546-2557",
        BIBSOURCE = "http://www.visionbib.com/bibliography/medical894pha1.html#TT185989"}

@article{bb190727,
        AUTHOR = "Tzoumas, S. and Kravtsiv, A. and Gao, Y. and Buehler, A. and Ntziachristos, V.",
        TITLE = "Statistical Molecular Target Detection Framework for Multispectral
Optoacoustic Tomography",
        JOURNAL = MedImg,
        VOLUME = "35",
        YEAR = "2016",
        NUMBER = "12",
        MONTH = "December",
        PAGES = "2534-2545",
        BIBSOURCE = "http://www.visionbib.com/bibliography/medical894pha1.html#TT185990"}

@article{bb190728,
        AUTHOR = "Lou, Y. and Wang, K. and Oraevsky, A.A. and Anastasio, M.A.",
        TITLE = "Impact of nonstationary optical illumination on image reconstruction
in optoacoustic tomography",
        JOURNAL = JOSA-A,
        VOLUME = "33",
        YEAR = "2016",
        NUMBER = "12",
        MONTH = "December",
        PAGES = "2333-2347",
        BIBSOURCE = "http://www.visionbib.com/bibliography/medical894pha1.html#TT185991"}

@article{bb190729,
        AUTHOR = "Drozdov, G. and Rosenthal, A.",
        TITLE = "Analysis of Negatively Focused Ultrasound Detectors in Optoacoustic
Tomography",
        JOURNAL = MedImg,
        VOLUME = "36",
        YEAR = "2017",
        NUMBER = "1",
        MONTH = "January",
        PAGES = "301-309",
        BIBSOURCE = "http://www.visionbib.com/bibliography/medical894pha1.html#TT185992"}

@article{bb190730,
        AUTHOR = "Brochu, F.M. and Brunker, J. and Joseph, J. and Tomaszewski, M.R. and Morscher, S. and Bohndiek, S.E.",
        TITLE = "Towards Quantitative Evaluation of Tissue Absorption Coefficients
Using Light Fluence Correction in Optoacoustic Tomography",
        JOURNAL = MedImg,
        VOLUME = "36",
        YEAR = "2017",
        NUMBER = "1",
        MONTH = "January",
        PAGES = "322-331",
        BIBSOURCE = "http://www.visionbib.com/bibliography/medical894pha1.html#TT185993"}

@article{bb190731,
        AUTHOR = "Javaherian, A. and Holman, S.",
        TITLE = "A Multi-Grid Iterative Method for Photoacoustic Tomography",
        JOURNAL = MedImg,
        VOLUME = "36",
        YEAR = "2017",
        NUMBER = "3",
        MONTH = "March",
        PAGES = "696-706",
        BIBSOURCE = "http://www.visionbib.com/bibliography/medical894pha1.html#TT185994"}

@article{bb190732,
        AUTHOR = "Chung, J. and Nguyen, L.",
        TITLE = "Motion Estimation and Correction in Photoacoustic Tomographic
Reconstruction",
        JOURNAL = SIIMS,
        VOLUME = "10",
        YEAR = "2017",
        NUMBER = "1",
        PAGES = "216-242",
        BIBSOURCE = "http://www.visionbib.com/bibliography/medical894pha1.html#TT185995"}

@article{bb190733,
        AUTHOR = "Kwon, K. and Moon, S.",
        TITLE = "Reconstruction Formula for Photoacoustic Tomography with Cylindrical
Detectors",
        JOURNAL = JMIV,
        VOLUME = "58",
        YEAR = "2017",
        NUMBER = "2",
        MONTH = "June",
        PAGES = "265-278",
        BIBSOURCE = "http://www.visionbib.com/bibliography/medical894pha1.html#TT185996"}

@article{bb190734,
        AUTHOR = "Ding, L. and Dean Ben, X.L. and Burton, N.C. and Sobol, R.W. and Ntziachristos, V. and Razansky, D.",
        TITLE = "Constrained Inversion and Spectral Unmixing in Multispectral
Optoacoustic Tomography",
        JOURNAL = MedImg,
        VOLUME = "36",
        YEAR = "2017",
        NUMBER = "8",
        MONTH = "August",
        PAGES = "1676-1685",
        BIBSOURCE = "http://www.visionbib.com/bibliography/medical894pha1.html#TT185997"}

@article{bb190735,
        AUTHOR = "Haltmeier, M. and Nguyen, L.V.",
        TITLE = "Analysis of Iterative Methods in Photoacoustic Tomography with
Variable Sound Speed",
        JOURNAL = SIIMS,
        VOLUME = "10",
        YEAR = "2017",
        NUMBER = "2",
        PAGES = "751-781",
        BIBSOURCE = "http://www.visionbib.com/bibliography/medical894pha1.html#TT185998"}

@article{bb190736,
        AUTHOR = "Mercep, E. and Dean Ben, X.L. and Razansky, D.",
        TITLE = "Combined Pulse-Echo Ultrasound and Multispectral Optoacoustic
Tomography With a Multi-Segment Detector Array",
        JOURNAL = MedImg,
        VOLUME = "36",
        YEAR = "2017",
        NUMBER = "10",
        MONTH = "October",
        PAGES = "2129-2137",
        BIBSOURCE = "http://www.visionbib.com/bibliography/medical894pha1.html#TT185999"}

@article{bb190737,
        AUTHOR = "Hauptmann, A. and Lucka, F. and Betcke, M. and Huynh, N. and Adler, J. and Cox, B. and Beard, P. and Ourselin, S. and Arridge, S.R.",
        TITLE = "Model-Based Learning for Accelerated, Limited-View 3-D Photoacoustic
Tomography",
        JOURNAL = MedImg,
        VOLUME = "37",
        YEAR = "2018",
        NUMBER = "6",
        MONTH = "June",
        PAGES = "1382-1393",
        BIBSOURCE = "http://www.visionbib.com/bibliography/medical894pha1.html#TT186000"}

@article{bb190738,
        AUTHOR = "Florea, M.I. and Basarab, A. and Kouame, D. and Vorobyov, S.A.",
        TITLE = "An Axially Variant Kernel Imaging Model Applied to Ultrasound Image
Reconstruction",
        JOURNAL = SPLetters,
        VOLUME = "25",
        YEAR = "2018",
        NUMBER = "7",
        MONTH = "July",
        PAGES = "961-965",
        BIBSOURCE = "http://www.visionbib.com/bibliography/medical894pha1.html#TT186001"}

@article{bb190739,
        AUTHOR = "Roy, S. and Borzi, A.",
        TITLE = "A New Optimization Approach to Sparse Reconstruction of
Log-Conductivity in Acousto-Electric Tomography",
        JOURNAL = SIIMS,
        VOLUME = "11",
        YEAR = "2018",
        NUMBER = "2",
        PAGES = "1759-1784",
        BIBSOURCE = "http://www.visionbib.com/bibliography/medical894pha1.html#TT186002"}

@article{bb190740,
        AUTHOR = "Gupta, M. and Mishra, R.K. and Roy, S.",
        TITLE = "Sparse Reconstruction of Log-Conductivity in Current Density Impedance
Tomography",
        JOURNAL = JMIV,
        VOLUME = "62",
        YEAR = "2020",
        NUMBER = "2",
        MONTH = "February",
        PAGES = "189-205",
        BIBSOURCE = "http://www.visionbib.com/bibliography/medical894pha1.html#TT186003"}

@article{bb190741,
        AUTHOR = "Olefir, I. and Tzoumas, S. and Yang, H. and Ntziachristos, V.",
        TITLE = "A Bayesian Approach to Eigenspectra Optoacoustic Tomography",
        JOURNAL = MedImg,
        VOLUME = "37",
        YEAR = "2018",
        NUMBER = "9",
        MONTH = "September",
        PAGES = "2070-2079",
        BIBSOURCE = "http://www.visionbib.com/bibliography/medical894pha1.html#TT186004"}

@article{bb190742,
        AUTHOR = "Morgan, M.R. and Broder, J.S. and Dahl, J.J. and Herickhoff, C.D.",
        TITLE = "Versatile Low-Cost Volumetric 3-D Ultrasound Platform for Existing
Clinical 2-D Systems",
        JOURNAL = MedImg,
        VOLUME = "37",
        YEAR = "2018",
        NUMBER = "10",
        MONTH = "October",
        PAGES = "2248-2256",
        BIBSOURCE = "http://www.visionbib.com/bibliography/medical894pha1.html#TT186005"}

@article{bb190743,
        AUTHOR = "Hossain, M.M. and Levy, B.E. and Thapa, D. and Oldenburg, A.L. and Gallippi, C.M.",
        TITLE = "Blind Source Separation-Based Motion Detector for Imaging
Super-Paramagnetic Iron Oxide (SPIO) Particles in Magnetomotive
Ultrasound Imaging",
        JOURNAL = MedImg,
        VOLUME = "37",
        YEAR = "2018",
        NUMBER = "10",
        MONTH = "October",
        PAGES = "2356-2366",
        BIBSOURCE = "http://www.visionbib.com/bibliography/medical894pha1.html#TT186006"}

@article{bb190744,
        AUTHOR = "Tang, S. and Sabonghy, E.P. and Chaudhry, A. and Shajudeen, P.S. and Islam, M.T. and Kim, N. and Cabrera, F.J. and Reddy, J.N. and Tasciotti, E. and Righetti, R.",
        TITLE = "A Model-Based Approach to Investigate the Effect of a Long Bone
Fracture on Ultrasound Strain Elastography",
        JOURNAL = MedImg,
        VOLUME = "37",
        YEAR = "2018",
        NUMBER = "12",
        MONTH = "December",
        PAGES = "2704-2717",
        BIBSOURCE = "http://www.visionbib.com/bibliography/medical894pha1.html#TT186007"}

@article{bb190745,
        AUTHOR = "Nguyen, T.N. and Do, M.N. and Oelze, M.L.",
        TITLE = "Visualization of the Intensity Field of a Focused Ultrasound Source In
Situ",
        JOURNAL = MedImg,
        VOLUME = "38",
        YEAR = "2019",
        NUMBER = "1",
        MONTH = "January",
        PAGES = "124-133",
        BIBSOURCE = "http://www.visionbib.com/bibliography/medical894pha1.html#TT186008"}

@article{bb190746,
        AUTHOR = "Frederick, C. and Ren, K. and Vallelian, S.",
        TITLE = "Image Reconstruction in Quantitative Photoacoustic Tomography with
the Simplified P_2 Approximation",
        JOURNAL = SIIMS,
        VOLUME = "11",
        YEAR = "2018",
        NUMBER = "4",
        PAGES = "2847-2876",
        BIBSOURCE = "http://www.visionbib.com/bibliography/medical894pha1.html#TT186009"}

@article{bb190747,
        AUTHOR = "Lucka, F. and Huynh, N. and Betcke, M. and Zhang, E. and Beard, P. and Cox, B. and Arridge, S.R.",
        TITLE = "Enhancing Compressed Sensing 4D Photoacoustic Tomography by
Simultaneous Motion Estimation",
        JOURNAL = SIIMS,
        VOLUME = "11",
        YEAR = "2018",
        NUMBER = "4",
        PAGES = "2224-2253",
        BIBSOURCE = "http://www.visionbib.com/bibliography/medical894pha1.html#TT186010"}

@article{bb190748,
        AUTHOR = "Naser, M.A. and Sampaio, D.R.T. and Munoz, N.M. and Wood, C.A. and Mitcham, T.M. and Stefan, W. and Sokolov, K.V. and Pavan, T.Z. and Avritscher, R. and Bouchard, R.R.",
        TITLE = "Improved Photoacoustic-Based Oxygen Saturation Estimation With
SNR-Regularized Local Fluence Correction",
        JOURNAL = MedImg,
        VOLUME = "38",
        YEAR = "2019",
        NUMBER = "2",
        MONTH = "February",
        PAGES = "561-571",
        BIBSOURCE = "http://www.visionbib.com/bibliography/medical894pha1.html#TT186011"}

@article{bb190749,
        AUTHOR = "Prakash, J. and Sanny, D. and Kalva, S.K. and Pramanik, M. and Yalavarthy, P.K.",
        TITLE = "Fractional Regularization to Improve Photoacoustic Tomographic Image
Reconstruction",
        JOURNAL = MedImg,
        VOLUME = "38",
        YEAR = "2019",
        NUMBER = "8",
        MONTH = "August",
        PAGES = "1935-1947",
        BIBSOURCE = "http://www.visionbib.com/bibliography/medical894pha1.html#TT186012"}

@article{bb190750,
        AUTHOR = "Haltmeier, M. and Nguyen, L.V.",
        TITLE = "Reconstruction Algorithms for Photoacoustic Tomography in Heterogeneous
Damping Media",
        JOURNAL = JMIV,
        VOLUME = "61",
        YEAR = "2019",
        NUMBER = "7",
        MONTH = "September",
        PAGES = "1007-1021",
        BIBSOURCE = "http://www.visionbib.com/bibliography/medical894pha1.html#TT186013"}

@article{bb190751,
        AUTHOR = "Zhao, H. and Chen, N. and Li, T. and Zhang, J. and Lin, R. and Gong, X. and Song, L. and Liu, Z. and Liu, C.",
        TITLE = "Motion Correction in Optical Resolution Photoacoustic Microscopy",
        JOURNAL = MedImg,
        VOLUME = "38",
        YEAR = "2019",
        NUMBER = "9",
        MONTH = "September",
        PAGES = "2139-2150",
        BIBSOURCE = "http://www.visionbib.com/bibliography/medical894pha1.html#TT186014"}

@article{bb190752,
        AUTHOR = "Drozdov, G. and Levi, A. and Rosenthal, A.",
        TITLE = "The Impulse Response of Negatively Focused Spherical Ultrasound
Detectors and Its Effect on Tomographic Optoacoustic Reconstruction",
        JOURNAL = MedImg,
        VOLUME = "38",
        YEAR = "2019",
        NUMBER = "10",
        MONTH = "October",
        PAGES = "2326-2337",
        BIBSOURCE = "http://www.visionbib.com/bibliography/medical894pha1.html#TT186015"}

@article{bb190753,
        AUTHOR = "Rathi, N. and Sinha, S.",
        TITLE = "Quantitative tissue characterization using discrete wavelet transform
of photoacoustic signals: a feasibility study",
        JOURNAL = SIViP,
        VOLUME = "13",
        YEAR = "2019",
        NUMBER = "7",
        MONTH = "October",
        PAGES = "1357-1365",
        BIBSOURCE = "http://www.visionbib.com/bibliography/medical894pha1.html#TT186016"}

@article{bb190754,
        AUTHOR = "Jin, H. and Zhang, R. and Liu, S. and Zheng, Y.",
        TITLE = "Fast and High-Resolution Three-Dimensional Hybrid-Domain
Photoacoustic Imaging Incorporating Analytical-Focused Transducer
Beam Amplitude",
        JOURNAL = MedImg,
        VOLUME = "38",
        YEAR = "2019",
        NUMBER = "12",
        MONTH = "December",
        PAGES = "2926-2936",
        BIBSOURCE = "http://www.visionbib.com/bibliography/medical894pha1.html#TT186017"}

@article{bb190755,
        AUTHOR = "Acosta, S.",
        TITLE = "Well-Posedness for Photoacoustic Tomography with Fabry-Perot Sensors",
        JOURNAL = SIIMS,
        VOLUME = "12",
        YEAR = "2019",
        NUMBER = "4",
        PAGES = "1669-1685",
        BIBSOURCE = "http://www.visionbib.com/bibliography/medical894pha1.html#TT186018"}

@article{bb190756,
        AUTHOR = "Boink, Y.E. and Manohar, S. and Brune, C.",
        TITLE = "A Partially-Learned Algorithm for Joint Photo-acoustic Reconstruction
and Segmentation",
        JOURNAL = MedImg,
        VOLUME = "39",
        YEAR = "2020",
        NUMBER = "1",
        MONTH = "January",
        PAGES = "129-139",
        BIBSOURCE = "http://www.visionbib.com/bibliography/medical894pha1.html#TT186019"}

@article{bb190757,
        AUTHOR = "Li, M. and Lan, B. and Sankin, G. and Zhou, Y. and Liu, W. and Xia, J. and Wang, D. and Trahey, G. and Zhong, P. and Yao, J.",
        TITLE = "Simultaneous Photoacoustic Imaging and Cavitation Mapping in
Shockwave Lithotripsy",
        JOURNAL = MedImg,
        VOLUME = "39",
        YEAR = "2020",
        NUMBER = "2",
        MONTH = "February",
        PAGES = "468-477",
        BIBSOURCE = "http://www.visionbib.com/bibliography/medical894pha1.html#TT186020"}

@article{bb190758,
        AUTHOR = "Baik, J.W. and Kim, J.Y. and Cho, S. and Choi, S. and Kim, J. and Kim, C.",
        TITLE = "Super Wide-Field Photoacoustic Microscopy of Animals and Humans In
Vivo",
        JOURNAL = MedImg,
        VOLUME = "39",
        YEAR = "2020",
        NUMBER = "4",
        MONTH = "April",
        PAGES = "975-984",
        BIBSOURCE = "http://www.visionbib.com/bibliography/medical894pha1.html#TT186021"}

@article{bb190759,
        AUTHOR = "Jin, H. and Zhang, R. and Liu, S. and Zheng, Y.",
        TITLE = "Rapid Three-Dimensional Photoacoustic Imaging Reconstruction for
Irregularly Layered Heterogeneous Media",
        JOURNAL = MedImg,
        VOLUME = "39",
        YEAR = "2020",
        NUMBER = "4",
        MONTH = "April",
        PAGES = "1041-1050",
        BIBSOURCE = "http://www.visionbib.com/bibliography/medical894pha1.html#TT186022"}

@article{bb190760,
        AUTHOR = "Yang, F. and Chen, Z. and Xing, D.",
        TITLE = "Single-Cell Photoacoustic Microrheology",
        JOURNAL = MedImg,
        VOLUME = "39",
        YEAR = "2020",
        NUMBER = "6",
        MONTH = "June",
        PAGES = "1791-1800",
        BIBSOURCE = "http://www.visionbib.com/bibliography/medical894pha1.html#TT186023"}

@article{bb190761,
        AUTHOR = "Ma, X. and Peng, C. and Yuan, J. and Cheng, Q. and Xu, G. and Wang, X. and Carson, P.L.",
        TITLE = "Multiple Delay and Sum With Enveloping Beamforming Algorithm for
Photoacoustic Imaging",
        JOURNAL = MedImg,
        VOLUME = "39",
        YEAR = "2020",
        NUMBER = "6",
        MONTH = "June",
        PAGES = "1812-1821",
        BIBSOURCE = "http://www.visionbib.com/bibliography/medical894pha1.html#TT186024"}

@article{bb190762,
        AUTHOR = "Sahlstrom, T. and Pulkkinen, A. and Tick, J. and Leskinen, J. and Tarvainen, T.",
        TITLE = "Modeling of Errors Due to Uncertainties in Ultrasound Sensor
Locations in Photoacoustic Tomography",
        JOURNAL = MedImg,
        VOLUME = "39",
        YEAR = "2020",
        NUMBER = "6",
        MONTH = "June",
        PAGES = "2140-2150",
        BIBSOURCE = "http://www.visionbib.com/bibliography/medical894pha1.html#TT186025"}

@article{bb190763,
        AUTHOR = "Mahurkar, A.G. and Seelamantula, C.S.",
        TITLE = "Minkowski-Algebra-Based Super-Sparse Array Design for
Super-Resolution Ultrasound Imaging",
        JOURNAL = SPLetters,
        VOLUME = "27",
        YEAR = "2020",
        PAGES = "1060-1064",
        BIBSOURCE = "http://www.visionbib.com/bibliography/medical894pha1.html#TT186026"}

@article{bb190764,
        AUTHOR = "Chen, J. and Chen, J. and Zhuang, R. and Min, H.",
        TITLE = "Multi-Operator Minimum Variance Adaptive Beamforming Algorithms
Accelerated With GPU",
        JOURNAL = MedImg,
        VOLUME = "39",
        YEAR = "2020",
        NUMBER = "9",
        MONTH = "September",
        PAGES = "2941-2953",
        BIBSOURCE = "http://www.visionbib.com/bibliography/medical894pha1.html#TT186027"}

@inproceedings{bb190765,
        AUTHOR = "Peng, B. and Huang, X. and Wang, S. and Jiang, J.",
        TITLE = "A Real-Time Medical Ultrasound Simulator Based on a Generative
Adversarial Network Model",
        BOOKTITLE = ICIP19,
        YEAR = "2019",
        PAGES = "4629-4633",
        BIBSOURCE = "http://www.visionbib.com/bibliography/medical894pha1.html#TT186028"}

@inproceedings{bb190766,
        AUTHOR = "Xiao, D. and Yiu, B.Y.S. and Chee, A.J.Y. and Yu, A.C.H.",
        TITLE = "Channel Count Reduction for Plane Wave Ultrasound Through Convolutional
Neural Network Interpolation",
        BOOKTITLE = ICIAR19,
        YEAR = "2019",
        PAGES = "II:442-451",
        BIBSOURCE = "http://www.visionbib.com/bibliography/medical894pha1.html#TT186029"}

@inproceedings{bb190767,
        AUTHOR = "Ben Daya, I. and Yeow, J.T.W. and Wong, A.",
        TITLE = "Compensated Row-Column Ultrasound Imaging Systems with Data-Driven
Point Spread Function Learning",
        BOOKTITLE = ICIAR19,
        YEAR = "2019",
        PAGES = "II:429-441",
        BIBSOURCE = "http://www.visionbib.com/bibliography/medical894pha1.html#TT186030"}

@inproceedings{bb190768,
        AUTHOR = "Tagawa, N. and Zhu, J.",
        TITLE = "Super-Resolution Ultrasound Imaging Based on the Phase of the Carrier
Wave Without Deterioration by Grating Lobes",
        BOOKTITLE = ICPR18,
        YEAR = "2018",
        PAGES = "2791-2796",
        BIBSOURCE = "http://www.visionbib.com/bibliography/medical894pha1.html#TT186031"}

@article{bb190769,
        AUTHOR = "Gee, A.H. and Prager, R.W. and Treece, G.M. and Berman, L.H.",
        TITLE = "Engineering a freehand 3D ultrasound system",
        JOURNAL = PRL,
        VOLUME = "24",
        YEAR = "2003",
        NUMBER = "4-5",
        MONTH = "February",
        PAGES = "757-777",
        BIBSOURCE = "http://www.visionbib.com/bibliography/medical894fh1.html#TT186032"}

@article{bb190770,
        AUTHOR = "Gee, A.H. and Treece, G.M. and Prager, R.W. and Cash, C.J.C. and Berman, L.H.",
        TITLE = "Rapid registration for wide field of view freehand three-dimensional
ultrasound",
        JOURNAL = MedImg,
        VOLUME = "22",
        YEAR = "2003",
        NUMBER = "11",
        MONTH = "November",
        PAGES = "1344-1357",
        BIBSOURCE = "http://www.visionbib.com/bibliography/medical894fh1.html#TT186033"}

@article{bb190771,
        AUTHOR = "Rousseau, F. and Hellier, P. and Barillot, C.",
        TITLE = "A Novel Temporal Calibration Method for 3-D Ultrasound",
        JOURNAL = MedImg,
        VOLUME = "25",
        YEAR = "2006",
        NUMBER = "8",
        MONTH = "August",
        PAGES = "1108-1112",
        BIBSOURCE = "http://www.visionbib.com/bibliography/medical894fh1.html#TT186034"}

@article{bb190772,
        AUTHOR = "Rousseau, F. and Hellier, P. and Letteboer, M.M.J. and Niessen, W.J. and Barillot, C.",
        TITLE = "Quantitative Evaluation of Three Calibration Methods for 3-D Freehand
Ultrasound",
        JOURNAL = MedImg,
        VOLUME = "25",
        YEAR = "2006",
        NUMBER = "11",
        MONTH = "November",
        PAGES = "1492-1501",
        BIBSOURCE = "http://www.visionbib.com/bibliography/medical894fh1.html#TT186035"}

@inproceedings{bb190773,
        AUTHOR = "Rousseau, F. and Barillot, C.",
        TITLE = "Quality Assessment of Electromagnetic Localizers in the Context of 3D
Ultrasound",
        BOOKTITLE = INRIA,
        YEAR = "2002",
        BIBSOURCE = "http://www.visionbib.com/bibliography/medical894fh1.html#TT186036"}

@inproceedings{bb190774,
        AUTHOR = "Pratikakis, I.E. and Barillot, C. and Darnault, P.",
        TITLE = "Towards Free-Hand 3-D Ultrasound",
        BOOKTITLE = INRIA,
        YEAR = "2002",
        BIBSOURCE = "http://www.visionbib.com/bibliography/medical894fh1.html#TT186037"}

@inproceedings{bb190775,
        AUTHOR = "Francois, R. and Fablet, R. and Barillot, C.",
        TITLE = "Robust statistical registration of 3D ultrasound images using texture
information",
        BOOKTITLE = ICIP03,
        YEAR = "2003",
        PAGES = "I: 581-584",
        BIBSOURCE = "http://www.visionbib.com/bibliography/medical894fh1.html#TT186038"}

@article{bb190776,
        AUTHOR = "Huang, Q.H. and Huang, Y. and Hu, W. and Li, X.L.",
        TITLE = "Bezier Interpolation for 3-D Freehand Ultrasound",
        JOURNAL = HMS,
        VOLUME = "45",
        YEAR = "2015",
        NUMBER = "3",
        MONTH = "June",
        PAGES = "385-392",
        BIBSOURCE = "http://www.visionbib.com/bibliography/medical894fh1.html#TT186039"}

@article{bb190777,
        AUTHOR = "Afsham, N. and Najafi, M. and Abolmaesumi, P. and Rohling, R.",
        TITLE = "A Generalized Correlation-Based Model for Out-of-Plane Motion
Estimation in Freehand Ultrasound",
        JOURNAL = MedImg,
        VOLUME = "33",
        YEAR = "2014",
        NUMBER = "1",
        MONTH = "January",
        PAGES = "186-199",
        BIBSOURCE = "http://www.visionbib.com/bibliography/medical894fh1.html#TT186040"}

@article{bb190778,
        AUTHOR = "Moon, H. and Ju, G. and Park, S. and Shin, H.",
        TITLE = "3D freehand ultrasound reconstruction using a piecewise smooth Markov
random field",
        JOURNAL = CVIU,
        VOLUME = "151",
        YEAR = "2016",
        NUMBER = "1",
        PAGES = "101-113",
        BIBSOURCE = "http://www.visionbib.com/bibliography/medical894fh1.html#TT186041"}

@article{bb190779,
        AUTHOR = "Baumgartner, C.F. and Kamnitsas, K. and Matthew, J. and Fletcher, T.P. and Smith, S. and Koch, L.M. and Kainz, B. and Rueckert, D.",
        TITLE = "SonoNet: Real-Time Detection and Localisation of Fetal Standard Scan
Planes in Freehand Ultrasound",
        JOURNAL = MedImg,
        VOLUME = "36",
        YEAR = "2017",
        NUMBER = "11",
        MONTH = "November",
        PAGES = "2204-2215",
        BIBSOURCE = "http://www.visionbib.com/bibliography/medical894fh1.html#TT186042"}

@article{bb190780,
        AUTHOR = "Toews, M. and Wells, W.M.",
        TITLE = "Phantomless Auto-Calibration and Online Calibration Assessment for a
Tracked Freehand 2-D Ultrasound Probe",
        JOURNAL = MedImg,
        VOLUME = "37",
        YEAR = "2018",
        NUMBER = "1",
        MONTH = "January",
        PAGES = "262-272",
        BIBSOURCE = "http://www.visionbib.com/bibliography/medical894fh1.html#TT186043"}

@article{bb190781,
        AUTHOR = "Rezajoo, S. and Sharafat, A.R.",
        TITLE = "Robust Estimation of Displacement in Real-Time Freehand Ultrasound
Strain Imaging",
        JOURNAL = MedImg,
        VOLUME = "37",
        YEAR = "2018",
        NUMBER = "7",
        MONTH = "July",
        PAGES = "1664-1677",
        BIBSOURCE = "http://www.visionbib.com/bibliography/medical894fh1.html#TT186044"}

@article{bb190782,
        AUTHOR = "Liu, S. and Feng, X. and Jin, H. and Zhang, R. and Luo, Y. and Zheng, Z. and Gao, F. and Zheng, Y.",
        TITLE = "Handheld Photoacoustic Imager for Theranostics in 3D",
        JOURNAL = MedImg,
        VOLUME = "38",
        YEAR = "2019",
        NUMBER = "9",
        MONTH = "September",
        PAGES = "2037-2046",
        BIBSOURCE = "http://www.visionbib.com/bibliography/medical894fh1.html#TT186045"}

@article{bb190783,
        AUTHOR = "Esposito, M. and Hennersperger, C. and Gobl, R. and Demaret, L. and Storath, M. and Navab, N. and Baust, M. and Weinmann, A.",
        TITLE = "Total Variation Regularization of Pose Signals With an Application to
3D Freehand Ultrasound",
        JOURNAL = MedImg,
        VOLUME = "38",
        YEAR = "2019",
        NUMBER = "10",
        MONTH = "October",
        PAGES = "2245-2258",
        BIBSOURCE = "http://www.visionbib.com/bibliography/medical894fh1.html#TT186046"}

@inproceedings{bb190784,
        AUTHOR = "Hu, Y.P. and Gibson, E. and Lee, L.L. and Xie, W. and Barratt, D.C. and Vercauteren, T. and Noble, J.A.",
        TITLE = "Freehand Ultrasound Image Simulation with Spatially-Conditioned
Generative Adversarial Networks",
        BOOKTITLE = RAMBO17,
        YEAR = "2017",
        PAGES = "105-115",
        BIBSOURCE = "http://www.visionbib.com/bibliography/medical894fh1.html#TT186047"}

@inproceedings{bb190785,
        AUTHOR = "Tetrel, L. and Chebrek, H. and Laporte, C.",
        TITLE = "Learning for Graph-Based Sensorless Freehand 3D Ultrasound",
        BOOKTITLE = MLMI16,
        YEAR = "2016",
        PAGES = "205-212",
        BIBSOURCE = "http://www.visionbib.com/bibliography/medical894fh1.html#TT186048"}

@inproceedings{bb190786,
        AUTHOR = "Conrath, J. and Laporte, C.",
        TITLE = "Towards Improving the Accuracy of Sensorless Freehand 3D Ultrasound by
Learning",
        BOOKTITLE = MLMI12,
        YEAR = "2012",
        PAGES = "78-85",
        BIBSOURCE = "http://www.visionbib.com/bibliography/medical894fh1.html#TT186049"}

@inproceedings{bb190787,
        AUTHOR = "Gilliam, A.D. and Hossack, J.A. and Acton, S.T.",
        TITLE = "Freehand 3D Ultrasound Volume Reconstruction via Sub-Pixel Phase
Correlation",
        BOOKTITLE = ICIP06,
        YEAR = "2006",
        PAGES = "2537-2540",
        BIBSOURCE = "http://www.visionbib.com/bibliography/medical894fh1.html#TT186050"}

@inproceedings{bb190788,
        AUTHOR = "Bogush, A.L. and Tuzikov, A.V.",
        TITLE = "3D Object Volume Measurement Using Freehand Ultrasound",
        BOOKTITLE = SCIA05,
        YEAR = "2005",
        PAGES = "1066-1075",
        BIBSOURCE = "http://www.visionbib.com/bibliography/medical894fh1.html#TT186051"}

@article{bb190789,
        AUTHOR = "Dutt, V. and Greenleaf, J.F.",
        TITLE = "Adaptive speckle reduction filter for log-compressed B-scan images",
        JOURNAL = MedImg,
        VOLUME = "15",
        YEAR = "1996",
        NUMBER = "6",
        MONTH = "December",
        PAGES = "802-813",
        BIBSOURCE = "http://www.visionbib.com/bibliography/medical894.html#TT186052"}

@article{bb190790,
        AUTHOR = "Czerwinski, R.N. and Jones, D.L. and O'Brien, W.D.",
        TITLE = "Detection of lines and boundaries in speckle images-application to
medical ultrasound",
        JOURNAL = MedImg,
        VOLUME = "18",
        YEAR = "1999",
        NUMBER = "2",
        MONTH = "February",
        PAGES = "126-136",
        BIBSOURCE = "http://www.visionbib.com/bibliography/medical894.html#TT186053"}

@inproceedings{bb190791,
        AUTHOR = "Czerwinski, R.N. and Jones, D.L. and O'Brien, W.D.",
        TITLE = "Ultrasound speckle reduction by directional median filtering",
        BOOKTITLE = ICIP95,
        YEAR = "1995",
        PAGES = "I: 358-361",
        BIBSOURCE = "http://www.visionbib.com/bibliography/medical894.html#TT186054"}

@inproceedings{bb190792,
        AUTHOR = "Czerwinski, R.N. and Jones, D.L. and O'Brien, W.D.",
        TITLE = "Edge detection in ultrasound speckle noise",
        BOOKTITLE = ICIP94,
        YEAR = "1994",
        PAGES = "III: 304-308",
        BIBSOURCE = "http://www.visionbib.com/bibliography/medical894.html#TT186055"}

@article{bb190793,
        AUTHOR = "Hao, X.H. and Gao, S. and Gao, X.",
        TITLE = "A novel multiscale nonlinear thresholding method for ultrasonic speckle
suppressing",
        JOURNAL = MedImg,
        VOLUME = "18",
        YEAR = "1999",
        NUMBER = "9",
        MONTH = "September",
        PAGES = "787-794",
        BIBSOURCE = "http://www.visionbib.com/bibliography/medical894.html#TT186056"}

@article{bb190794,
        AUTHOR = "Achim, A. and Bezerianos, A. and Tsakalides, P.",
        TITLE = "Novel Bayesian multiscale method for speckle removal in medical
ultrasound images",
        JOURNAL = MedImg,
        VOLUME = "20",
        YEAR = "2001",
        NUMBER = "8",
        MONTH = "August",
        PAGES = "772-783",
        BIBSOURCE = "http://www.visionbib.com/bibliography/medical894.html#TT186057"}

@article{bb190795,
        AUTHOR = "Cohen, B. and Dinstein, I.",
        TITLE = "New maximum likelihood motion estimation schemes for noisy ultrasound
images",
        JOURNAL = PR,
        VOLUME = "35",
        YEAR = "2002",
        NUMBER = "2",
        MONTH = "February",
        PAGES = "455-463",
        BIBSOURCE = "http://www.visionbib.com/bibliography/medical894.html#TT186058"}

@inproceedings{bb190796,
        AUTHOR = "Cohen, B. and Dinstein, I.",
        TITLE = "Motion Estimation in Noisy Ultrasound Images by Maximum Likelihood",
        BOOKTITLE = ICPR00,
        YEAR = "2000",
        PAGES = "Vol III: 182-185",
        BIBSOURCE = "http://www.visionbib.com/bibliography/medical894.html#TT186059"}

@article{bb190797,
        AUTHOR = "Michailovich, O.V. and Adam, D.",
        TITLE = "A novel approach to the 2-D blind deconvolution problem in medical
ultrasound",
        JOURNAL = MedImg,
        VOLUME = "24",
        YEAR = "2005",
        NUMBER = "1",
        MONTH = "January",
        PAGES = "86-104",
        BIBSOURCE = "http://www.visionbib.com/bibliography/medical894.html#TT186060"}

@article{bb190798,
        AUTHOR = "Michailovich, O.V. and Adam, D.",
        TITLE = "A high-resolution technique for ultrasound harmonic imaging using
sparse representations in gabor frames",
        JOURNAL = MedImg,
        VOLUME = "21",
        YEAR = "2002",
        NUMBER = "12",
        MONTH = "December",
        PAGES = "1490-1503",
        BIBSOURCE = "http://www.visionbib.com/bibliography/medical894.html#TT186061"}

@article{bb190799,
        AUTHOR = "Michailovich, O.V. and Adam, D.",
        TITLE = "Robust estimation of ultrasound pulses using outlier-resistant
de-noising",
        JOURNAL = MedImg,
        VOLUME = "22",
        YEAR = "2003",
        NUMBER = "3",
        MONTH = "March",
        PAGES = "368-381",
        BIBSOURCE = "http://www.visionbib.com/bibliography/medical894.html#TT186062"}

Last update:Sep 28, 2020 at 12:04:43