21.8.1 Tomographic Images, CAT, CT, Overviews, Surveys, Datasets

Chapter Contents (Back)
Survey, Tomography. Tomography. CT. CAT.

Cormack, A.M.[Allan M.],
Representation of a Function by Its Line Integrals with Some Radiological Applications,
Applied Physics(34), 1963, pp. 2722-2727. The work that led to the 1979 Nobel Prize. BibRef 6300

Cormack, A.M.,
Some Early Radiotherapy Optimization Work,
IJIST(6), No. 1, 1995, pp. 2-5. BibRef 9500

Cormack, A.M.,
The Radon Transform on a Family of Curves in the Plane,
OAMS(14), 1981, pp. 325-330. BibRef 8100

Herman, G.T., (Ed.)
Special Issue: Computerized Tomography,
PIEEE(71), No. 3, March 1983, pp. 291-435 (all). BibRef 8303

Kak, A.C., Roberts, B.A.,
Reconstruction from Projections: Applications in Computerized Tomography,
HPRIP86(649-693). BibRef 8600

Farrell, E.J.[Edward J.], Yang, W.C.[Wen C.], and Zappulla, R.A.[Rosario A.],
Animating 3-D CT Imaging,
IEEE_CGA(5), No. 12, December, 1985, pp. 26-32. BibRef 8512

Herman, G.T., Kuba, A.,
Discrete Tomography,
IJIST(9), No. 2-3, 1998, pp. U4-U5. 9805
BibRef

Browne, J.A., Koshy, M., Stanley, J.H.,
On the Application of Discrete Tomography to CT-Assisted Engineering and Design,
IJIST(9), No. 2-3, 1998, pp. 78-84. 9805
BibRef

Walden, J.,
Analysis of the direct Fourier method for computer tomography,
MedImg(19), No. 3, March 2000, pp. 211-222.
IEEE Top Reference. 0110
BibRef

Natterer, F.[Frank], Ritman, E.L.[Erik L.],
Past and future directions in x-ray computed tomography (CT),
IJIST(12), No. 4, 2002, pp. 175-187.
WWW Link. 0212
BibRef

Jorgensen, S.M., Eaker, D.R., Vercnocke, A.J., Ritman, E.L.[Erik L.],
Reproducibility of Global and Local Reconstruction of Three-Dimensional Micro-Computed Tomography of Iliac Crest Biopsies,
MedImg(27), No. 4, April 2008, pp. 569-575.
IEEE DOI 0804
BibRef

Bronnikov, A.V.[Andrei V.],
Theory of quantitative phase-contrast computed tomography,
JOSA-A(19), No. 3, March 2002, pp. 472-480.
WWW Link. 0204
BibRef

Vardi, Y.,
Metrics useful in network tomography studies,
SPLetters(11), No. 3, March 2004, pp. 353-355.
IEEE Abstract. 0404
BibRef

Park, J.S., Chung, M.S., Hwang, S.B., Lee, Y.S., Har, D.H., Park, H.S.,
Visible Korean Human: Improved Serially Sectioned Images of the Entire Body,
MedImg(24), No. 3, March 2005, pp. 352-360.
IEEE Abstract. 0501
BibRef

Yendiki, A.[Anastasia], Fessler, J.A.[Jeffrey A.],
Analysis of Observer Performance in Known-Location Tasks for Tomographic Image Reconstruction,
MedImg(25), No. 1, January 2006, pp. 28-41.
IEEE DOI 0601
BibRef

Yendiki, A.[Anastasia], Fessler, J.A.[Jeffrey A.],
Analysis of observer performance in unknown-location tasks for tomographic image reconstruction,
JOSA-A(24), No. 12, December 2007, pp. B99-B109.
WWW Link. 0801
BibRef

Shi, H.R., Fessler, J.A.,
Quadratic Regularization Design for 2-D CT,
MedImg(28), No. 5, May 2009, pp. 645-656.
IEEE DOI 0905
BibRef

Kak, A.C., and Slaney, M., (Eds.),
Principles of Computerized Tomographic Imaging,
IEEE_PressNew York, 1988.
WWW Link. Survey, Tomography. Buy this book: Principles of Computerized Tomographic Imaging (Classics in Applied Mathematics) BibRef 8800

Herman, G.T., Kuba, A., (Eds.),
Advances in Discrete Tomography and Its Applications,
Springer2007. ISBN 978-0-8176-3614-2
WWW Link. Survey, Tomography. Buy this book: Advances in Discrete Tomography and its Applications (Applied and Numerical Harmonic Analysis) BibRef 0700

Herman, G.T., Kuba, A.,
Discrete tomography in medical imaging,
PIEEE(91), No. 10, October 2003, pp. 1612-1626.
IEEE DOI 0310
Survey, Tomography. BibRef

Herman, G.T.[Gabor T.],
Fundamentals of Computerized Tomography: Image Reconstruction from Projections,
Springer-Verlag2009. ISBN: 978-1-85233-617-2 Second Edition.
WWW Link. Buy this book: Fundamentals of Computerized Tomography: Image Reconstruction from Projections (Advances in Pattern Recognition) 0910
BibRef

Ritman, E.L.,
Evolution of medical tomographic imaging: As seen from a Darwinian perspective,
PIEEE(91), No. 10, October 2003, pp. 1483-1491.
IEEE DOI 0310
BibRef

Gureyev, T.E.[Timur E.], Nesterets, Y.I.[Yakov I.], Pavlov, K.M.[Konstantin M.], Wilkins, S.W.[Stephen W.],
Computed tomography with linear shift-invariant optical systems,
JOSA-A(24), No. 8, August 2007, pp. 2230-2241.
WWW Link. 0801
BibRef

Gureyev, T.E.[Timur E.], Kozlov, A.[Alexander], Paganin, D.M.[David M.], Nesterets, Y.I.[Yakov I.], de Hoog, F.[Frank], Quiney, H.M.[Harry M.],
On the van Cittert-Zernike theorem for intensity correlations and its applications,
JOSA-A(34), No. 9, September 2017, pp. 1577-1584.
DOI Link 1709
For a quantized electromagnetic beam in a coherent state. Imaging systems, Image formation theory, Noise in imaging systems, Partial coherence in imaging, X-ray imaging BibRef

Myers, G.R.[Glenn R.], Gureyev, T.E.[Timur E.], Paganin, D.M.[David M.],
Stability of phase-contrast tomography,
JOSA-A(24), No. 9, September 2007, pp. 2516-2526.
WWW Link. 0801
BibRef

Kalender, W.A.[Willi A.],
Computed Tomography: Fundamentals, System Technology, Image Quality, Applications,
WileyJanuary 2006. ISBN: 978-3-89578-216-9 2nd Edition
HTML Version. Buy this book: Computed Tomography: Fundamentals, System Technology, Image Quality, Applications 0905
BibRef

Kalender, W.A.[Willi A.],
Computed Tomography: Fundamentals, System Technology, Image Quality, Applications, 2nd Edition,
WileyNovember 2009. ISBN: 978-3-89578-317-3.
HTML Version. Buy this book: Computed Tomography: Fundamentals, System Technology, Image Quality, Applications 0905
BibRef

Kalender, W.A.[Willi A.],
Computed Tomography: Fundamentals, System Technology, Image Quality, Applications, 3rd Edition,
WileySeptember 2011. ISBN: 978-3-89578-317-3
HTML Version. 1109
BibRef

Grangeat, P.[Pierre], (Editor).
Tomography,
Wiley-ISTEJuly 2009. ISBN: 978-1-84821-099-8
HTML Version. Buy this book: Tomography 0905
BibRef

Clackdoyle, R., Defrise, M.,
Tomographic Reconstruction in the 21st Century,
SPMag(27), No. 4, 2010, pp. 60-80.
IEEE DOI 1007
BibRef

Pougaza, D.B.[Doriano-Boris], Mohammad-Djafari, A.[Ali], Bercher, J.F.[Jean-Francois],
Link between copula and tomography,
PRL(31), No. 14, 15 October 2010, pp. 2258-2264.
Elsevier DOI 1003
Copula; Tomography; Joint and marginal distributions; Image reconstruction; Additive and multiplicative backprojection; Maximum entropy BibRef

Rahmat, M.F.[Mohd Fua'ad], Thuku, I.T.[Iliya Tizhe],
Review of Tomographic Imaging using Finite Element Method,
Sensors(135), No. 12, December 2011, pp. 1-19.
HTML Version. 1112
BibRef

Cierniak, R.[Robert],
X-Ray Computed Tomography in Biomedical Engineering,
Springer2011, ISBN: 978-0-85729-026-7.
WWW Link. Survey, Tomography. Buy this book: X-Ray Computed Tomography in Biomedical Engineering 1102
BibRef

Bornefalk, H., Persson, M.,
Theoretical Comparison of the Iodine Quantification Accuracy of Two Spectral CT Technologies,
MedImg(33), No. 2, February 2014, pp. 556-565.
IEEE DOI 1403
X-ray spectra BibRef

Roelandts, T.[Tom], Batenburg, K.J.[K. Joost], den Dekker, A.J.[Arnold J.], Sijbers, J.[Jan],
The reconstructed residual error: A novel segmentation evaluation measure for reconstructed images in tomography,
CVIU(126), No. 1, 2014, pp. 28-37.
Elsevier DOI 1407
Computed tomography BibRef

Venkatakrishnan, S.V., Mohan, K.A.[K. Aditya], Ziabari, A.K.[Amir Koushyar], Bouman, C.A.[Charles A.],
Algorithm-Driven Advances for Scientific CT Instruments: From Model-Based to Deep Learning-Based Approaches,
SPMag(39), No. 1, January 2022, pp. 32-43.
IEEE DOI 2201
Instruments, Computed tomography, Volume measurement, Signal processing algorithms, X-rays, Reconstruction algorithms BibRef

Ruben, G.[Gary], Pinar, I.[Isaac], Brown, J.M.C.[Jeremy M. C.], Schaff, F.[Florian], Pollock, J.A.[James A.], Crossley, K.J.[Kelly J.], Maksimenko, A.[Anton], Hall, C.[Chris], Hausermann, D.[Daniel], Uesugi, K.[Kentaro], Kitchen, M.J.[Marcus J.],
Full Field X-Ray Scatter Tomography,
MedImg(41), No. 8, August 2022, pp. 2170-2179.
IEEE DOI 2208
Photonics, Imaging, X-ray imaging, Detectors, Scattering, Lighting, Computed tomography, Compton, scatter, tomography, X-ray imaging, preclinical imaging BibRef

Shi, Y.Y.[Yong-Yi], Xia, W.J.[Wen-Jun], Wang, G.[Ge], Mou, X.Q.[Xuan-Qin],
Blind CT Image Quality Assessment Using DDPM-Derived Content and Transformer-Based Evaluator,
MedImg(43), No. 10, October 2024, pp. 3559-3569.
IEEE DOI 2411
Computed tomography, Transformers, Image quality, Feature extraction, Image reconstruction, Distortion, Noise, transformer-based image quality evaluator BibRef


Jaus, A.[Alexander], Seibold, C.[Constantin], Hermann, K.[Kelsey], Shahamiri, N.[Negar], Walter, A.[Alexandra], Giske, K.[Kristina], Haubold, J.[Johannes], Kleesiek, J.[Jens], Stiefelhagen, R.[Rainer],
Towards Unifying Anatomy Segmentation: Automated Generation of a Full-Body CT Dataset,
ICIP24(41-47)
IEEE DOI 2411
Image segmentation, Computed tomography, Knowledge based systems, Anatomical structure, Predictive models, Data models, Anatomy BibRef

Bleichrodt, F.[Folkert], Batenburg, K.J.[K. Joost],
Automatic Optimization of Alignment Parameters for Tomography Datasets,
SCIA13(489-500).
Springer DOI 1311
BibRef

Declerck, J., Subsol, G., Thirion, J.P., Ayache, N.J.,
Automatic Retrieval of Anatomical Structures in 3D Medical Images,
CVRMed95(XX-YY) BibRef 9500

Chapter on Medical Applications, CAT, MRI, Ultrasound, Heart Models, Brain Models continues in
Fluorescence Tomography, X-ray Fluorescence Computed Tomography XFCT .


Last update:Nov 26, 2024 at 16:40:19